TABLE 6.3
Cell retention devices/options and some important parameters for their use
System
Working
volume
range (L)
Max. cell
conc.
(x 1E06
cells/mL)
Max.
perfusion
rate (L/d)
Cell
debris
removal
Residence
time in
equipment
Single use
Additional
equipment
Cells used
Virus
production
demonstrated
Reference
Spin filter
0.5–500
80
0.5–500
No
n.a.
No
Peristaltic
pump
CHO,
Hybridoma,
BHK21
RABV
[ 32, 54]
HFBR
0.004–0.1
72
288
No
Process time Yes
Duet pump,
incubator,
oxygenator
MDCK,
AGE1.CR,
HEK293,
Huh7.5
IAV, MVA,
HIV, HCV
[ 6, 28, 46, 55]
PBBR
0.5–100
150
200
No
Constant
Yes
Peristaltic
pumps,
controller,
incubator
Vero,
HEK293,
MRC-5,
Huh7.5,
MDCK,
CHO
IAV, SARS-
CoV-2, HCV,
VSV, Ad5,
AAV, IPV,
RABV, HAV,
CHIKV
[ 4, 6, 56– 59]
TFF
0.01–2000
200
100
No
10 s
Yes
Levitronix
pump,
peristaltic
pumps
AGE1.CR,
BHK21,
HEK293,
CHO
IAV, YFV, Ad5,
ZIKV
[ 5, 44, 60]
ATF
0.5–5000
130–360
1200
No
1–2 min
Yes
ATF
controller,
peristaltic
pumps
MDCK,
AGE1.CR,
BHK21,
EB66, CHO,
PBG.PK2.1
IAV, MVA,
ZIKV,
YFV, Ad5
[ 5, 36– 38,
44, 45, 61]
150
Bioprocessing of Viral Vaccines